1 SAMSUNG ER-290 ELECTRONIC CASH REGISTER www.AnchorData.co.ukAnchor Data Systems (NI) Ltd Unit 36 North City Business Centre Duncair
10 www.AnchorData.co.uk
11BASIC FEATURES AND FUNCTIONS 2-1. KEYBOARD LAYOUT FEED CLERK X/TM 7 8 9 4 8 12 PLU RA - +% -% 4 5 6 3 7 11 CHARGE PO CANCEL RF VD 1
12BASIC FEATURES AND FUNCTIONS VD - VOID key is used for item void operation in REG and VOID mode. RF - RETURN MERCHANDISE key is used for
13 www.AnchorData.co.uk
14BASIC FEATURES AND FUNCTIONS CHECK - Used to finalize the transaction in cheque sales in REG and VOID mode. Used to convert check into c
15BASIC FEATURES AND FUNCTIONS 2-3. CONTROL LOCK The Keylock has 7 positions. OFF VOID
16BASIC FEATURES AND FUNCTIONS 2-5. DISPLAY DPT RPT A M O U N T
17 turn the power on again. 2-8. BATTERY SYSTEM This model is equipped with a battery system that provides back up power to the reg
18PROGRAMMING Setting up features before use. When you finish with this program, make it a rule to depress the CASH/TEND key.
19PROGRAMMING STATUS TABLE No. S Y S T E M O P T I O N STATUS 1 Print GRAND TOTAL in X,Z report. YES = 0 NO = 1 2 Print GROSS T
2 INTRODUCTION...5
20PROGRAMMING No. S Y S T E M O P T I O N STATUS 12 Print data of VOID position in report YES = 0 NO = 1 Select information of
21 NO = 1 18 Allow Check Cashing. YES = 0 PROGRAMMING No. S Y S T E M O P T I O N STATUS Select Information of Clerk 19
22PROGRAMMING 3-2. DECIMAL POINT & TAX INFORMATION This programming is for setting up the decimal point and tax information. Decimal point in
233-4. PERCENT(%) Percent(%) key is programmed either positive or negative, as an open or preset amount of percentage. This is set up and calcul
24 You can use the Clerk function as standard. Or you can set up the System option to allow. You can input a secret code for each cler
25PROGRAMMING 3-6-2. CHANGING THE SECRET CLERK CODE You can change the existing secret code of a clerk. By inputting the old secret No. follo
26PROGRAMMING 3-7. DEPARTMENT This programming consists of two parts. One is OPEN DEPARTMENT, and the other is PRESET PRICE DEPARTMENT.
27 3-7-2. PRESET PRICE DEPARTMENT Preset price department consists of preset price and status. Preset price can be programmed
28 Department NOTE !! Refer to 3-7-1. OPEN DEPARTMENT about HDLO and status. 3-8-2. PRESET PRICE PLU
29PROGRAMMING 3-9. DATE This is related to date sequence. You have to program according to following date sequence. n1 n2 n3 n
33-8. PLU (Price Look Up)... 27 3-8-
303-11. REGISTER NUMBER You can set up a register number which consists of 2 figures. n1 n2 - #/NS Example. S
31 YOUR RECEIPT THANK YOU 2 5 - 1 2 - 1 9 9 7 7 1 1 . . . . . 1 0 . 0 0 T 1 7 2 2 . . .
32 * . . . . . . . . . 0 - % * . . . . 1 0 . 0 0 0 - % * . . . . . . . . . 0 + % * . . . . . 0 . 0
33 4. OPERATIONS Now, you can operate this model. This part explains how to operate the cash register. The tender keys are
34 OPERATION 4-1-1. CLERK SIGN ON You have to program the System option about Clerk and set up the secret code of the Clerk before operating t
35 4-1-2. CLERK SIGN OFF When you sign off current Clerk, depress the O key an
36OPERATION 4-2. DEPARTMENT This operation is when you enter a sales item using the department key. Watch the display when you are ope
37 4-2-3. DEPARTMENT REPEAT ENTRY This is applied to either open or preset price
38
39OPERATION 4-2-7. SINGLE ITEM DEPARTMENT For example if Department 4 is programmed as a single item, Department 4 will not operate as a s
44-9-1. OPEN DRAWER ...48 4-9-2. N
40 4-3-3. PLU OVERRIDING Press the RA key before entering the number of the PLU in case of overriding of the preset PLU.
41OPERATION 4-3-5. PLU MULTIPLICATION 2 X/TM ── Quantity
42OPERATION 4-4 . PERCENT These keys are used to add or subtract a percent rate to or from an individual sale entry item or the entire sale. Eac
43OPERATION 4-4-2. PERCENT ON A DEPARTMENT OR PLU FOR THE MANUAL RATE You can operate this key without the preset rate. The manual rate is the
44OPERATION 4-4-3. PERCENT ON SALE TOTAL ┌ -% ‥‥‥ SUBTOTAL - │ In case of preset rate
45OPERATION 4-5. RETURN MERCHANDISE This operation is used to return merchandise. See the follows. ┌ DPT RF │
46
47OPERATION 4-6. VOID 4-6-1. LAST ITEM VOID / ERROR ITEM This key corrects the last item or voids the last item only. 1 0 0
48 CASH/TEND ── Tender
49
5INTRODUCTION This Electronic Cash Register is designed for general retail applications requiring efficient management control and simplicity of o
50 Example. Paid out 20.00. 2 0 0 0 PO
51OPERATION 4-11-2. RECEIPT BUFFER Receipt issued when required. Set up System option 21. NOTE !! Refer to 3-1. SYSTEM OPTION about receip
52 OPERATION 4-12. SUBTOTAL 2 0 0 0 DPT1 ── Sale item
53 Tender on Check
54 CHARGE ── Non-amount Tender on Charge 4-13-6. POST TENDER Allows
55REPORTS System reports are divided into two basic categories; "X", or read-only and "Z", or read & reset to zero
56REPORTS 6-2. CASH-IN-DRAWER REPORT After depressing the SUBTOTAL key in X mode, Cash-in-drawer Read Report will be issued. You can check
57 Financial report is divided into two. One is Daily financial report and the other is Period financial report. You can issue Daily fi
58Finalcial Daily Read X CASH/TEND Read & Reset Z Financial Period Read X CHARGE Read & Reset Z T I M E Read X X/TM R
59 REPORTS FINANCIAL REPORT -- PAID OUT COUNTER -- TIMELY TOTAL 2 5 - 1 2 - 1 9 9 7 @ . .
6INITIAL SET-UP INSTRUCTION The following instructions describe how to unpack and start up the cash register. 1-1.
60 REPORTS @ . . . . . . . . . 2 * . . . . . - 5 . 0 0 - % @ . . . . . . . . . 0 * . . . . . . 0 . 0 0 + %
61REPORTS 6-5. TIME REPORT If you depress the X/TM key in X mode, and then it will issue Time Read Report. If you depress the X/TM key
62REPORTS 6-6-1. FROM-TO PLU REPORT Enter the start number of PLU to be read, depress the PLU key, then the last number of PLU to be read, d
63 After depressing the PLU key in Z mode, PLU Read and Reset Report will be issued. REPORTS 6-7. CLERK REPORT
64 www.AnchorData.co.uk
65 SYSTEM BALANCING 7-1. DEPARMENT SALES TOTAL The sum of all department totals: Add all positive departments,
66 SPECIFICATION ·POWER : AC 110V/230V ± 10%, 50/60 ㎐ ·OPERATING TEMPERATURE : 0℃ - 40℃ ·MEMORY PROTECTION : A
7INITIAL SET-UP INSTRUCTION 1-3. INSTALL PAPER IN THE PRINTER 1-3-1. Remove the printer cover and cut or tear the end of the paper roll
8 INITIAL SET-UP INSTRUCTION 1-3-5. For journal use: Insert the leading end of the paper into the paper take-up spool, wind the paper tw
9INITIAL SET-UP INSTRUCTION 1-4. CHANGING RIBBON 1-4-1. Remove the printer cover. 1-4-2. Lift up ink ribbon. 1-4-3. Insert the new ink ribbon.